Communication Protocol for Baracoda ScanWear/ToughRunners Scanners
Sept. 07 12/26
Command ID 0xA5
Description Set data suffix
Length 0-32
payload suffix
Response 0 (1 = ERROR)
Command ID 0xA6
Description Get data prefix
Length 0
payload None
Response 0-32 bytes: prefix
Default settings :
No prefix
Command ID 0xA7
Description Set data prefix
Length 0-32
payload prefix
Response 0 (1 = ERROR)
Command ID 0xA8
Description Get AIM symbology ID transmission
Length 0
payload None
Response A :
0 = disabled
1 = enabled
Default settings :
A = 0
Command ID 0xA9
Description Set AIM symbology ID transmission
Length 1
payload A :
0 = disabled
1 = enabled
Response 0 (1 = ERROR)